Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2004.05a
- /
- Pages.32-35
- /
- 2004
Fire-Resistance Characteristics of Shield Tunnel Concrete Linings
쉴드터널 콘크리트 라이닝의 내화특성
Abstract
In recent years a number of catastrophic tunnel fires, the Euro tunnel, the Mont Blanc tunnel, the Tauem tunnel and the Gotthard tunnel, have occurred and inflicted serious damages to European countries. If a fire occurs in shield tunnels, the reinforced concrete segment linings playing as an important structural member is expected to damage severely and finally can be caused the collapse of tunnel. The purpose of this study is to evaluate the performance of concrete segment lining under heat exposure and to obtain information to assist a new technical approach to fighting fires in tunnels. In order to evaluate the fire-resistance performance of concrete segment by adding Polypropylene fibers, fire tests using the RABT heat-load curve is carried out. The temperature rise of this curve is very rapid up to
Keywords