Fire-Resistance Characteristics of Shield Tunnel Concrete Linings

쉴드터널 콘크리트 라이닝의 내화특성

  • 박해균 (삼성물산(주)건설부문 토목사업본부 토목기술팀) ;
  • 이명섭 (삼성물산(주)건설부문 토목사업본부 토목기술팀) ;
  • 전상은 (삼성물산(주)건설부문 기술본부 기술연구소) ;
  • 박동규 (삼성물산(주)건설부문 토목사업본부 토목기술팀)
  • Published : 2004.05.01

Abstract

In recent years a number of catastrophic tunnel fires, the Euro tunnel, the Mont Blanc tunnel, the Tauem tunnel and the Gotthard tunnel, have occurred and inflicted serious damages to European countries. If a fire occurs in shield tunnels, the reinforced concrete segment linings playing as an important structural member is expected to damage severely and finally can be caused the collapse of tunnel. The purpose of this study is to evaluate the performance of concrete segment lining under heat exposure and to obtain information to assist a new technical approach to fighting fires in tunnels. In order to evaluate the fire-resistance performance of concrete segment by adding Polypropylene fibers, fire tests using the RABT heat-load curve is carried out. The temperature rise of this curve is very rapid up to $1200^{\circ}C$ within 5 minutes, and duration time of the $1200^{\circ}C$ exposure is 55 minutes. From the fire test, it was found that the explosive spalling was rapidly reduced by adding polypropylene fibers and this method is considered as an effective fireproof material to upgrade fire safety in tunnels economically.