The Comparative Effect of Time-Frequency Distribution Function in a Time-Frequency Domain Reflectometry System

시간-주파수 영역 반사파 계측 시스템에서 다양한 시간-주파수 분포 함수의 영향 연구

  • Kwak, Ki-Seok (Dept. of Electrical & Electronic Engineenng, Yonsei Univ.) ;
  • Tok, Son-Choe (Dept. of Electrical & Electronic Engineenng, Yonsei Univ.) ;
  • Tae, Sung-Yoon (Dept. of Electrical Engineering, Changwon National Univ.) ;
  • Jin, Bae-Park (Dept. of Electrical & Electronic Engineenng, Yonsei Univ.) ;
  • Jae, Won-Kho (Dept. of Computer Aided Control Engineering, Yuhan College)
  • 곽기석 (연세대학교 전기전자공학과) ;
  • 최덕선 (연세대학교 전기전자공학과) ;
  • 윤태성 (창원대학교 전기공학과) ;
  • 박진배 (연세대학교 전기전자공학과) ;
  • 고재원 (유한대학 컴퓨터제어과)
  • Published : 2004.07.14

Abstract

The time-frequency domain reflectometry(TFDR) is well known to detect and locate a fault in a coaxial cable[3]. Traditional reflectometry methods have been achieved in either the time domain or frequency domain only. However, the time-frequency domain reflectometry utilizes time and frequency information of a reflected signal passed through a cable to detect and locate the fault. The purpose of this paper is to find appropriate time-frequency distribution function suitable for a TFDR system. Choosing the appropriate time-frequency distribution function implies one can detect the fault and estimate the location accurately. We consider and compare adequate time-frequency distribution function on the basis of experimental results.

Keywords