DMT 방식 전력선 통신의 전자파 장애에 관한 연구

The study of emissive electromagnetic interference DMT PLC(Power Line Communication)

  • 최종필 (아주대학교 전자공학부) ;
  • 신철재 (아주대학교 전자공학부)
  • Choi, Jong-Pil (School of Electrical and Computer Engineering, Ajou University) ;
  • Shin, Chull-Chai (School of Electrical and Computer Engineering, Ajou University)
  • 발행 : 2003.11.15

초록

In this paper, we studied the radiated electric field of power-line with DMT signal source in the frequency range of $1.7{\sim}30 MHz$. First, we made the midium voltage power-line communication model for PLC and calculated the current through the power-line using the impedance of the power-line model. Second, we calculated the radiated electric field in power range $-50{\sim}-30 dBm$ using the calculated current. Consequently, the calculated emissive electromagnetic field from the DMT signal is similar to the measured result. So this study is applicable to the standard regulation of electromagnetic interference for PLC.

키워드