The Performance of AC PDP with Grooved Dielectric Structure in High Xe Contents

  • Kim, Tae-Jun (School of Electrical & Computer Engineering, Seoul National University) ;
  • Bae, Hyun-Sook (School of Electrical & Computer Engineering, Seoul National University) ;
  • Jeong, Dong-Cheol (School of Electrical & Computer Engineering, Seoul National University) ;
  • Whang, Ki-Woong (School of Electrical & Computer Engineering, Seoul National University)
  • 발행 : 2003.07.09

초록

We reported an AC PDP structure with grooved front panel dielectric layer. The structure exhibits low breakdown voltage, better luminance, and better endurance to crosstalk in high Xe contents. It also shows less luminous efficacy then conventional structure because of the thinner dielectric layer, but we can apply the higher Xe contents to the grooved dielectric structure, which results in the higher luminous efficacy. We made experiments with the Xe contents from 4 to16% and total gas pressure from 400 to 600Torr. The grooved dielectric structure shows the improvement of 20% luminous efficacy and 17% luminance. The firing voltages lower about 40V at 600Torr and Xe 12, 16%. The discharge characteristics of grooved dielectric structure are verified also with 2D simulation.

키워드