Water Quality Estimation Using Spectroradiometer and SPOT Data

  • Hsiao, Kuo-Hsin (Researcher, Energy and Resources Laboratories, Industrial Technology Research Institute) ;
  • Wu, Chi-Nan (Researcher, Energy and Resources Laboratories, Industrial Technology Research Institute) ;
  • Liao, Tzu-Yi (Researcher, Energy and Resources Laboratories, Industrial Technology Research Institute)
  • Published : 2003.11.03

Abstract

A field spectroradiometer SE-590 was used to measure the spectral reflectance of water body. The reflectance was calculated as the ratio of surface water radiance to the standard whiteboard radiance nearly measured at the same time. Water samples were taken simultaneously for determining their chlorophyll-a, suspended solid (SS) and transparency. The relationships between those water quality parameters and spectral reflectance were analy zed using stepwise multiple regression to derive optimal prediction models . The multiple regression was also applied to the SE-590 simulated SPOT bands. The SPOT image of the same day was also analyzed using the same method to compare the statistical results. It showed that the multiple regression models using the SE-590 reflectance data got the best water quality prediction results. The evaluated RMS error of chlorophyll-a, SS and transparency of water quality parameters were 0.57 ug/l, 0.2 mg/l and 0.17 m, respectively, and the RMS errors were 0.36 ug/l, 0.49 mg/l and 0.42 m for SPOT data, respectively. The SE-590 simulated SPOT three bands data obtained the worst results and the RMS errors were 1.77 ug/l, 0.49 mg/l and 0.37 m, respectively.