대한전기학회:학술대회논문집 (Proceedings of the KIEE Conference)
- 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
- /
- Pages.261-263
- /
- 2003
500 kV 개폐충격전압시스템의 비교시험
Intercomparison Tests of National Standard Measuring System for Switching Impulse Voltage rated 500 kV
-
Kim, I.S.
(KERI) ;
-
Kim, M.K.
(KERI) ;
- Jeong, J.Y. (KERI) ;
-
Moon, I.W.
(KERI)
- 발행 : 2003.10.31
초록
This paper represents the development of national standard(NS) for switching impulse(SI) voltage measuring system rated 500 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with CSIRO of Australia. According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, a measurement uncertainty and step response characteristics were satisfied with the requisite for NS.
키워드