한국콘크리트학회:학술대회논문집 (Proceedings of the Korea Concrete Institute Conference)
- 한국콘크리트학회 2003년도 가을 학술발표회 논문집
- /
- Pages.581-586
- /
- 2003
직각천공방식으로 패커를 설치한 균열보수공법의 보수재 주입특성
Evaluation of Injection Property of Crack Repair Method by Right Angle Drill Method with Packer
초록
The objective of this study is to evaluate the injection performance of crack repair method in concrete structure. To improve the quality of the concrete structure caulking material was injected into the crack of building that were planned to be demolished and injection properties of various repair method were compared and assessed according to type of crack. Results from the test showed that when cracks and injection port were integrated and the injection port wasn't blocked repair material was able to be injected even below around 40㎏/㎠ pressure. Moreover, effective pressure each type of packer showed wide range varying from 200-400㎏/㎠. As for drill method for injection port, core drill method has shown to be more effective compared to the air pump method
키워드