Experimental Research on Development and Splices Length in High-Strength Concrete Flexural Members

고강도 콘크리트 휨부재의 정착 및 겹침이음길이에 관한 실험적 연구

  • 이기열 (전남대학교 토목공학과) ;
  • 김우 (전남대학교 토목공학과) ;
  • 정기오 (전남대학교 토목공학과)
  • Published : 2003.05.01

Abstract

This paper presents the test results of 24 beam-end specimens to investigate the effect of concrete strength and cover thickness on the development resistance capacity in tensile lap splice length regions. The results showed that as higher strength concrete was employed, nor only development resistance capacity was influenced by cover thickness, but also more sufficient safety factor reserved shorter than the lap splice length provision in current design code. From experimental research results, high-strength concrete development length was not inverse ratio of ($\sqrt{f_{ck}}$) but directly inverse of $f_{ck}$, and it is also said that there is a certain limit length of the embedded steel over which the assumption of uniform bond stress distribution is valid specially for high-strength concrete not having a same embed length such as normal-strength concrete in current design criteria hypothesis.

Keywords