Experimental Study on Failure Behavior of Plain Concrete - Biaxial Stress Test

콘크리트 파괴거동특성의 실험적 연구I-이축응력시험

  • 이상근 (비앤티 엔지니어링㈜ 기술연구소) ;
  • 이상민 (비앤티 엔지니어링㈜) ;
  • 박상순 (비앤티 엔지니어링㈜ 기술연구소) ;
  • 한상훈 (충북대학교 토목공학과) ;
  • 송영철 (한전전력연구원 원자력연구실)
  • Published : 2003.05.01

Abstract

Two different strength types of plain concrete plate specimens (200$\times$200$\times$60mm) were tested under different biaxial load combinations. The specimens were subjected to biaxial combinations covering the three regions of compression-compression, compression-tension, and tension-tension. The loading platens with Teflon pads were used to reduce a confining effect in boundary surface between the concrete specimen and the solid platen. The principal deformations in the specimens were recorded, and the failure modes along with each stress ratio were examined. Based on the strength data, the failure envelops were developed for each type of plain concrete. The biaxial stress-strain responses of concrete plate specimens for three biaxial loading regions were also plotted. The test data indicated that the strength of concrete under biaxial compression ($f_2 / f_1$$_1$=-1/-1) is about 17 percent larger than under uniaxial compression.

Keywords