System Integration Test System Integration Test of Containment Structure of Nuclear Power Plant Using Fiber Optic Sensor

광섬유센서를 이용한 원자력 발전소 격납구조물의

  • 김기수 (호서대학교 벤처대학원 첨단산업기술학과)
  • Published : 2003.10.01

Abstract

In this paper, a Fiber Bragg Grating (FRG) sensor system is described and FBGs are well-suited for long term and extremely severe experiments, where traditional strain gauges fail. In the system, a reflect wave-length measurement method which employs a tunable light source to find out the center wave-length of FBG sensor is used. We apply the FBG system to nuclear energy Power Plant for structural integrity test to measure the displacement of the structure under designed pressure and to check the elasticity of the structure by measuring the residual strain. The system works very well and it is expected that it can be used for a real-time strain. temperature and vibration detector of smart structure.

Keywords