An Experimental Study of the Seismic Isolation Systems for Equipment Isolation : EPS

기기면진을 위한 면진장치의 거동분석실험 (I) : FPS 거동분석

  • 전영선 (한국원자력연구소 종합안전평가부) ;
  • 김민규 (한국원자력연구소 종합안전평가부) ;
  • 최인길 (한국원자력연구소 종합안전평가부) ;
  • 김영중 (한국기계연구원 구조시스템연구부)
  • Published : 2003.09.01

Abstract

This paper presents the results of experimental studies on the equipment isolation effect in the nuclear containment. For this purpose, shaking table tests were performed. The isolation system, known as Friction Pendulum System (FPS), combines the concepts of sliding bearings and pendulum motion was selected. Peak ground acceleration, bidirectional motion, effect of vertical motion and frequency contents of selected earthquake motions were considered. Finally, it is presented that the FPS systems are effective for the small equipment isolation. Key word equipment isolation, nuclear containment, shaking table test, Friction Pendulum System (FPS)

Keywords