Hot Cell Facility for Demonstration of Advanced Spent Fuel Conditioning Process
사용후핵연료 차세대관리 종합공정 실증시설
Abstract
The advanced spent fuel conditioning process(ACP) was proposed to reduce considerably the overall volume and radioactivity for effective management of the PWR spent fuel in respects on safety and economy. The ACP is under research and development, and have scheduled to perform hot test for demonstration of the ACP after several years. For hot test, hot cell facility of
국내 경수로형 사용후핵연료의 효율적인 관리를 위하여 현재 건식처리공정으로 개발 중에 있는 차세대관리 종합공정의 실증시험이 계획되어 있다. 실증시험의 수행을 위해서는 기밀성이 유지되는