Experiment on the Vitrification of Nonflammable Wastes Using AP-200L Plasma Torch

AP-200L 토치를 이용한 비가연성 방사성폐기물 고온용융처리

  • 최종락 (한수원㈜ 원자력환경기술원) ;
  • 유병수 (한수원㈜ 원자력환경기술원) ;
  • 김천우 (한수원㈜ 원자력환경기술원) ;
  • 박종길 (한수원㈜ 원자력환경기술원) ;
  • 하종현 (한수원㈜ 원자력환경기술원)
  • Published : 2003.11.01

Abstract

The high temperature melting test for nonflammable wastes using a plasma torch was conducted. The AP-200L hollow cathode type plasma torch was installed at the pilot plasma melting furnace in NETEC. The surrogates were prepared to simulate concrete, soil and their mixture with steel. The experimental conditions such as feeding rate, the distance between melts surface and torch nozzle, torch rotation speed, gas flow rate and pressure in the furnace were decided. Basic parameters such as temperatures of cooling waters, off-gas and torch power were measured. The vitrified samples were analyzed by SEM/EDS.

원자력발전소로부터 발생하는 비가연성 고체폐기물의 모사시료에 대해 플라즈마 토치를 이용하여 고온용융처리 시험을 실시하였다 실험은 AP-200L 공동형 플라즈마토치를 사용하여 콘크리트, 흙과 금속이 포함되는 혼합물에 대하여 약 50시간 정도 수행되었다. 처리속도, 토치의 노즐과 용융물 표면과 간격, 토치 회전속도, 토치가스 유속 그리고 용융로의 압력 등 몇몇 실험조건을 사전에 결정하였으며, 냉각수 온도, 배가스 온도, 토치출력변화 등 기본 파라메타를 측정하였다. 유리화된 시료는 SEM/EDS로 분석하였다.

Keywords