Determination of Lead(II) at Nafion-DTPA-Glycerol-Modified Glassy Carbon Electrodes

  • Park, Eun-Heui (Department of Chemistry, Chonnam National University) ;
  • Park, Chan-Ju (Department of Chemistry, Chonnam National University) ;
  • Chung, Keun-Ho (Department of Chemistry Education, Chonnam National University)
  • 발행 : 2003.06.01

초록

Determination of Lead(II) using nafion-DTPA (diethylene triamine pentaacetic acid)-glycerol-modified glassy carbon electrodes is described. Lead(II) is accumulated at the electrode by complexing with the DTPA, reduced, and detected by differential pulse voltammetry. In this study, we demonstrate that at a preconcentration time of 5min the nafion-DTPA-glycerol-modified glassy carbon electrode has a linear calibration curve at range 1.0${\times}$10$\^$-9/M∼1.0${\times}$10$\^$-7/M in pH 4.0 buffer solution. The detection limit(3$\sigma$) is as low as 5.0${\times}$10$\^$-6/M. This method is applied to the determination of lead(II) in certified reference material and the result agrees satisfactorily with the certified value.