대한용접접합학회:학술대회논문집 (Proceedings of the KWS Conference)
- 대한용접접합학회 2003년도 춘계학술발표대회 개요집
- /
- Pages.117-119
- /
- 2003
영광 #1/2 복수기 누수부 보수공사
Yeonggwang #1/2 steam condenser leakage repair works
초록
Power plant efficiency and availability depend greatly on condenser performance. However, during commissioning of Yeonggwang #1/2 steam condenser sodium leakage occurred, because of tube to tubesheet only roll expanding. Therefore this report is explaining that pre-test for the shake of improvement reliable repair processes & selected sampling tube re-expansion in-situ applications.