Time and distance of tulip-inversion in various shaped tube

다양한 형상의 관내에서 화염전파시 튤립화염으로 전환되는 시간과 거리

  • 정상훈 (한국과학기술원 기계공학과) ;
  • 이은도 (한국과학기술원 기계공학과) ;
  • 김남일 (한국과학기술원 기계공학과) ;
  • 신현동 (한국과학기술원 기계공학과)
  • Published : 2002.06.07

Abstract

The tulip-inversion of flames in half-open tubes was investigated experimentally. Experiments was carried out in tubes with various shapes. The image of a flame propagation were pictured by HICCD(High speed intensified CCD) and the dynamic pressure of tubes was measured by a piezo pressure sensor. By analyzing the images of the flame propagation, we found the time and the distance for the occurrence of tulip-inversion. Regardless of the shapes of tubes, time of tulip-inversion are similar and inversely proportional to the burning velocity. But distances have different tendency. In a straight tube, the distance of tulip-inversion increases when the burning velocity increases. But in a converging tube, the distance of tulip-inversion decreases when a burning velocity increases. And the distance of tulip-inversion in a converging tube is much smaller than the distance of tulip-inversion in a straight tube. These results are caused by the deceleration of a flame when the diameter of a hole in open-side of a tube is small. The deceleration causes little effect on the time of tulip-inversion.