The electrochemical study on Viologen SA monolayer using QCM

수정진동자를 이용한 Viologen Self-Assembly 단분자막의 전기화학적 특성

  • Published : 2002.05.17

Abstract

In this paper, the electrochemical behavior of Viologen self assembly monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self assemvly process of Viologen was monitored using resonant frequency $({\Delta}F)$ and resonant resistance(R). QCM measurements indicated a mass adsorption for Viologen assembling on the gold sufrace with a frequency change about 135[Hz] and calculated its surface coverage($\Gamma$) to be $3.5273{\times}10^{-9}[mol/cm^{2}]$. Also reversible redox process was observed and analyzed with ionic interaction at the Viologen/solution interface using ${\Delta}F$.

Keywords