Estimation of Flow-induced Vibration characteristics on Plugged Steam Generator

관막음된 증기발생기 전열관의 유체유발진동 특성 평가

  • 조봉호 (전북대학교 대학원 항공우주공학과) ;
  • 유기완 (전북대학교 기계항공시스템공학부) ;
  • 박치용 (한전 전력연구원 원자력연구실) ;
  • 박수기 (한전 전력연구원 원자력연구실)
  • Published : 2002.11.01

Abstract

In this study, we investigate the plugging effect on the CE type steam generator tube. The natural frequency and mode shape will be changed due to decrease of the effective mass distribution along the tube. We compared the variation of stability ratio for plugged tube with that for unplugged one. The natural frequency increased because of removing the cooling water inside the steam generator tube, but the stability ratio decreased inversely because of changing the vibrational model shape. We also investigated the turbulent excitation effect.

Keywords