대한기계학회:학술대회논문집 (Proceedings of the KSME Conference)
- 대한기계학회 2002년도 학술대회지
- /
- Pages.597-600
- /
- 2002
펌프장에서 Sump내 흡입구 주위의 유동해석
Flow Analyses around Intake within Sump in a Pump Station
- 발행 : 2002.08.01
초록
In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Uneven flow distribution can also increase or decrease the power consumption with a change in total developed head. To avoid these sump problems pump station designers are considered intake structure dimensions, such as approaching upstream, baffle size, sump width, width of pump cell and so on. From this background, flow characteristics of intake within sump are Investigated numerically to obtain the optimal sump design data. The sump model is designed in accordance with HI code.