Numerical Study on Seismic Resistance of Flat Plate-Column Connections

플랫 플레이트-기둥 접합부의 내진성능에 대한 해석연구

  • 박홍근 (서울대학교 건축학과) ;
  • 최경규 (서울대학교 대학원 건축학과) ;
  • 황영현 (서울대학교 대학원 건축학과)
  • Published : 2002.05.01

Abstract

Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column connection. In the present study, numerical studies were performed for interior connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, shear, torsional moment around the connection were investigated. Based on the findings of the numerical studies, the disadvantages of current design methods were discussed.

Keywords