An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form

내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구

  • 김경민 (청주대학교 대학원) ;
  • 손성운 (청주대학교 대학원) ;
  • 김기철 ((주) 선엔지니어링 종합건축사사무소) ;
  • 오선교 ((주) 선엔지니어링 종합건축사사무소) ;
  • 한천구 (청주대학교)
  • Published : 2002.05.01

Abstract

In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

Keywords