Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2002.05a
- /
- Pages.23-28
- /
- 2002
Thermal Crack Characteristics of Concrete Walls with Pipe Cooling
파이프 쿨링 공법 적용에 따른 벽체구조물의 온도균열 특성
Abstract
This paper reports the performance results of hydration heat control of mass concrete walls with pipe cooling system. The thickness of walls ranged from 0.9 to 2.2m. In order to investigate the effect of pipe cooling on the thermal and thermal crack characteristics, the pipe cooling was conducted for 42 walls, and the investigation of thermal cracks was conducted for 14 walls. Based on the investigation, the pipe cooling method decreased the peak temperature of about 13-2
Keywords