Development of high speed synchronous control system for real time 3D eye imaging equipment using deadbeat observer

데드비트 관측기를 이용한 망막의 3차원 실시간 영상화를 위한 고속 동기제어 시스템 개발

  • Ko Jong-Sun (Dept. of Electric-Electronic & Information Engineering) ;
  • Kim Young-Il (Dept. of Electric-Electronic & Information Engineering) ;
  • Lee Tae-hoon (Dept. of Electric-Electronic & Information Engineering)
  • 고종선 (원광대학교 전기전자정보공학부) ;
  • 김영일 (원광대학교 전기전자정보공학부) ;
  • 이태훈 (원광대학교 전기전자정보공학부)
  • Published : 2002.11.01

Abstract

To show a retina shape and thickness on the computer monitor, a laser has been used in Scanning Laser Ophthalmoscope(SLO) equipment using the travelling difference. This method requires exact synchronous control of laser travelling in optic system to show a clear 3-dimensional image of retina. To obtain this image, this exact synchronism is very important for making the perfect plane scanning. In this study, a synchronous control of the galvanometer using deadbeat torque observer to make 3-dimensional retina image is presented. For the more, a very simple mathematical model of the galvanometer is approved by experimental result.

Keywords