산업용 터보팬의 진동절연에 관한 연구

The Study on Vibration Isolation of Industrial Turbo-fan

  • 박익필 (동아대학교 대학원 기계공학과) ;
  • 김동영 (동아대학교 대학원 기계공학과) ;
  • 권용수 (동아대학교 대학원 기계공학과) ;
  • 안찬우 (동아대학교 기계산업시스템 공학부)
  • 발행 : 2001.11.01

초록

A turbo-fan is easily exposed to noise and vibration as against other industrial machines and the majority of them is subject to be damaged by vibration. The most usual problem of vibration in a turbo-fan is resonance so the case of being composed of iron sheet structure with low strength like a turbo-fan should be taken seriously. In this paper, FFT(Fast Fourier Transform) and Order tracking method were used to analyze factors of vibration in a turbo-fan and hereby with proper selection of vibration isolator, we wanted to reduce vibration of base. After Order tracking, we knew resonance occurred in rotational frequency 23 Hz(1400 rpm) at the casing and the bearing. After the test of base vibration using vibration isolators, the spring isolator was more effective than the robber isolator in the base vibration and the vibration isolating is more effective in the case that the isolating pad is adhered to the bottom of the isolating spring.