Finite Element Analysis of End-to-End Anastomosis of Coronary Artery with Elastic Surrounding Tissue

탄성경계조직을 가진 관상동맥의 end-to-end 문합에 대한 유한요소해석

  • 한근조 (동아대학교 기계공학과) ;
  • 김태형 (경남정보대학 기계계열) ;
  • 안성찬 (동아대학교 기계공학과 대학원) ;
  • 심재준 (동아대학교 기계공학과 대학원)
  • Published : 2001.11.01

Abstract

A finite element analysis of end-to-end artery/PTFE anastomosis has been presented in this study to evaluate the distribution of compliance in the vicinity of the anastomosis due to any mismatch in compliance characteristics. But, In these studies it was assumed that the artery and PTFE have the simple cylindrical shape representing the fatty tissue surrounding the coronary artery. And the fatty tissue was considered as the elastic surrounding materials in the finite element analysis. The simulation results were obtained as follows : 1. A fatty tissue was effect to reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis of different material because a hypercompliant zone become narrorw and a compliance discrepancy decrease between the artery and the PTFE about 70%. And radial direction displacement distribution with respect to distance in the vicinity of a artery/PTFE anastomosis was similiar. 2. The variation of PTFE thckness reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis about 25%.

Keywords