Seismic Design Guidelines for Welded Steel Oil Storge Tank (KS B 6225)

강제 석유 저장 탱크(KS B 6225)의 내진 설계 기준 개선 안

  • 박종률 (현대엔지니어링(주), 화공플랜트사업부, 기계부) ;
  • 오택열 (경희대학교, 기계산업시스템부)
  • Published : 2001.11.01

Abstract

Recommended seismic design guide for the flat bottom vertical-cylindrical oil storage tanks in KS B 6225 is presented. Under earthquake excitations, the hydrodynamic pressure exerted on the tank walls produces overturning moment which may cause either a failure of the anchors or a buckling of the tank shell near its base. The basis for establishing design loads due to hydrodynamic pressure is described including seismic zone risk map in Korea, zone coefficients and the essential facilities factor. This procedure for calculating applied compressive stress on the shell base subjecting to seismic load and for estimating the allowable buckling stress is described.

Keywords