부분 예혼합 화염의 예열공기 연소특성

Preheated Air Combustion Characteristics of Partially Premixed Flame

  • 이승영 (부산대학교 대학원 기계공학과) ;
  • 이종호 (부산대학교 대학원 기계공학과) ;
  • 전충환 (부산대학교 기계공학부, 기계기술연구소) ;
  • 장영준 (부산대학교 기계공학부, 기계기술연구소)
  • 발행 : 2001.11.01

초록

OH radical and NOx have been measured in a methane-air partially premixed flame using PLIF technique to define preheated air combustion characteristics. The temperature of mixture is determined by 300K, 400K, 600K and 800K below the auto-ignition temperature respectively. Flame height increases as equivalence ratio increased. As initial enthalpy is supplied, the radius of flame was increased and much amount of yellow flame in rich equivalence ratio was observed. This is due to the faster burning velocity. Also initial oxidization begins earlier as the initial temperature of mixture increased. It means that height of premixed flame front decreased. This phenomenon can be observed OH PLIF image. The qualitative analysis of OH concentration in the PLIF image shows that overall OH concentration increases with equivalence ratio and the initial temperature of mixture increased. At the preheating temperature goes up, axial gradient of OH concentration is less steep than that of lower temperature condition. This may identify that combustion reacts continuously, so preheated air combustion can evade the local heating and make high temperature indiscriminately in the overall reaction zone.

키워드