Leakage Error Improvement of the Intensity with a single freqency

단일 주파수를 갖는 음향 인텐시티의 누설오차 개선

  • 정의봉 (부산대학교 기계공학부) ;
  • 안세진 (부산대학교 대학원 기계설계공학) ;
  • 정호경 (부산대학교 대학원 기계설계공학과)
  • Published : 2001.11.01

Abstract

Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed date of a harmonic signal with a single frequency is formated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

Keywords