하중기준 변화에 따른 노후공동주택의 내진성능 향상 기법에 대한 고찰

A Study of Improving Method of Seismic-Resisting Capacity of Deteriorated Apartment Houses according to Load Change

  • 정미영 (대한주택공사 주택연구소) ;
  • 이수진 (대한주택공사 주택연구소) ;
  • 박경헌 (대한주택공사 주택연구소) ;
  • 박지영 (대한주택공사 주택연구소) ;
  • 김상연 (대한주택공사 주택연구소) ;
  • 윤영호 (대한주택공사 주택연구소)
  • 발행 : 2001.11.01

초록

In 2000, Standard Design Loads for Building was changed especially in seismic load. According to the change, seismic-resisting capacity of deteriorated apartment houses has to be reestimated. This research is to propose seismic-strengthening and improving methods of structural efficiency of RC deteriorated apartment houses. The analysis models were shear-wall system(36/58/79$m^{2}$) and beam-column system(11/19/25py) which were constructed in early 1980 and didn't consider seismic load. The definite methods are addition of shear walls and lightening of load. The story-drifts of shear wall systems exceed allowable story-drifts so that two methods was applied. The story-drifts of beam-columns system satisfy allowable story-drifts, thus the latter is applied. The seismic-resisting capacity of these systems was improved by the two methods. This research will be helpful to remodel deteriorated apartment houses.