Quasi-Static Test for Seismic Performance of R/C Bridge Piers Retrofitted with Glassfibers

준정적실험에 의한 섬유보강된 철근콘크리트 교각의 내진성능 평가

  • 이대형 (경북도립 경도대학 건설환경공학과) ;
  • 이재형 (중앙대학교 대학원) ;
  • 정영수 (중앙대학교 건설대학 토목공학과) ;
  • 박진영 (중앙대학교 대학원)
  • Published : 2001.05.01

Abstract

Recent earthquakes in California and Japan caused extensive damage to highway bridge structures. It is also thought that during probable earthquakes bridge structures in Korea could be failed due to the structural deficiencies, which were nonseismically designed and constructed before 1992. In these regards, innovative strengthening methods have been developed to repair reinforced concrete bridge columns, especially by glassfiber sheet bonding methods which are widely used today. The primary objective of this research is to investigate the seismic behavior of RC bridge columns retrofitted with composite straps and to propose pertinent guidelines of repair and rehabilitation method for earthquake resistant design procedure of RC bridges which are located in low or moderate seismicity regions. Six scaled-down concrete test specimens were made with test variables such as lap splice ratio, axial force ratio, confinement ratio, composite straps in the plastic hinge region. Pertinent design guidelines could be developed for the earthquake resistant design of RC bridge piers retrofitted with glassfibers in low or moderate seismic region.