A Study on the Operating Characteristics of Variable Speed Pump for In-Line Booster Pumping Station

직결식 변속펌프의 운전 방안에 대한 연구

  • 박종문 (한국종합엔지니어링 기계전기부) ;
  • 최성일 (한국종합엔지니어링 기계전기부) ;
  • 노형운 (조선대학교 항공조선공학부) ;
  • 서상호 (숭실대학교 기계공학과) ;
  • 김상균 (한국수자원공사 수도설비처)
  • Published : 2001.11.01

Abstract

In the systems with largely pipe head loss, variable speed pumps are generally used because substantial energy saving can be expected from such systems by controlling pump speed and also they offer simpler maintenance and operational ease even in conditions where abrupt changes In flow rate and head can occur. The invertor or the fluid coupling system are mainly adopted to control the rotating speed. In this paper, operating conditions at Migum pressing pump station(5 stage), where the fluid coupling system was the first installed for KOWACO, are investigated and analysed so that information thus gained can be usefully employed in the efficient operation of variable speed pump in new installations of in-line booster pumping station.

Keywords