Performance Evaluation of Motor-Operated Valve Using Electrical Signatures

  • Park, Joo-Moon (Department of Electrical Engineering, Chungnam National Univ.) ;
  • Joo, Hyung-Jun (Department of Electrical Engineering, Chungnam National Univ.) ;
  • Jung, Jae-Cheon (Korea Power Engineering Company Inc. (KOPEC)) ;
  • Sung, Key-Yong (Korea Institute of Nuclear Safety (KINS)) ;
  • Seong, Se-Jin (Department of Electrical Engineering, Chungnam National Univ.)
  • Published : 2001.10.01

Abstract

This paper is to see the availability of electrical signatures as a means for evaluating the performance and monitoring mechanical anomalies of (MOVs). To estimate motor torque, two methods such as d-q frame conversion and air-gap method are suggested and estimated results are compared with measured values. The error between measured and estimated torques is within acceptable error bound with below $1\%$ under varied load. Frequency domain analysis of calculated torque has been done as well. It is shown that monitoring of peak frequency could give useful clues to detect anomalies of MOV. As results, electrical signatures at MOV motor is expected to be an available tool for estimation of motor capacity and monitoring of electrical and mechanical abnormalities.

Keywords