액체의 유전상수 정밀측정용 크로스 커패시터 전극 개발

Development of a Cross Capacitor Electrode for Measurements of Liquids Dielectric Constants

  • 김한준 (한국표준과학연구원 전기그룹) ;
  • 이래덕 (한국표준과학연구원 전기그룹) ;
  • 강전홍 (한국표준과학연구원 전기그룹) ;
  • ;
  • 한상옥 (한국표준과학연구원 전기그룹)
  • ;
  • ;
  • ;
  • YU. p. Semenov ;
  • 발행 : 2000.07.01

초록

Using the principle of the cross capacitor, a precise system for measuring the electric constants of liquids has been developed. The four electrodes of the cross capacitor were formed around fused-silica tube by plating a gold film. The effect of a non-uniform tube wall ok the measured permittivity was investigated As the individual characteristics of the tubes were determined to be constant, the pure dielectric constants extracted from any effect of the fused-silica material could be precisely derived with uncertainty of less than ${\pm}$ 0.02∼0.05 %.

키워드