Evaluation of Ultimate Pressure Capacity of Prestressed Concrete Containment Building Considering Aging of Materials

재료의 경년상태를 고려한 PSC격납건물의 극한내압능력 평가

  • 이상근 (한전 전력연구원 원자력연구실) ;
  • 송영철 (한전 전력연구원 원자력연구실) ;
  • 권용길 (충북대학교 토목공학과 대학원) ;
  • 한상훈 (충북대학교 토목공학과)
  • Published : 2000.04.01

Abstract

The purpose of this study is to predict long-term structural safety on the Yonggwang Unit 3 prestressed concrete containment building. The aging-related degradations of its main structural materials are investigated and the effects of the property variation of time-dependent materials on the structural behavior of containment building are also assessed through the analysis on the ultimate pressure capacity. The nonlinear finite element analyses for both the design criteria condition a the present aging condition are conducted to assess the present structural capacity of the containment building As a result, it is verified that the structural capacity of the Yonggwang Unit 3 containment building under the present aging condition is judged to be still rugged. n addition, the sensitivity of the ultimate pressrue capacity of containment building according to th degradation levels of the structural materials are assessed. Finally, it is showed that the sensitivity levels are in the order of the tendon, rebar and concrete in case of individual material degradations, and the tendon-rebar, tendon-concrete and rebar-concrete in case of coupled material degradations.

Keywords