주상복합구조에서 전이보와 내부기둥 접합부의 반복횡하중 실험

Cyclic Loading Test of Interior Deep-Beam Lower-Column Joint in Upper-shear Wall Lower-Frame Structure

  • 이한선 (정회원, 고려대학교 건축공학과) ;
  • 김상연 (정회원, 대한주택공사) ;
  • 고동우 (정회원, 고려대 건축공학과) ;
  • 권기혁 (서울시립대 건축공학과) ;
  • 최성모 (정회원, 경민대 건축공학과)
  • 발행 : 2000.04.01

초록

In case of strong earthquake, upper-sheat wall lowe-frame structures show the weak-story failure at lower part. Where we should guarantee sufficient strength, energy dissipation capacity and ductility. In this study, a typical structure was selected for a prototype and four 1:2.5 scaled models, representing the subassemblages including the interior column and the deep beam, were constructed. Experimental parameters include transverse reinforcement ratio and axial force. The non- linear behavior of the subassemblages subjected to the cyclic lateral displac-ement were evaluated through investigation of the ultimate strength, ductility, load-deformation characteristics. From the results of the tests on 4 specimens, it is concluded that the strength increased as the axial force increased and the ductility increased as the transverse reinforcement ratio increased.

키워드