Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference (한국초전도저온공학회:학술대회논문집)
- 2000.02a
- /
- Pages.48-51
- /
- 2000
Behavior of cryogenic gases in a closed space
밀폐된 공간에서 초저온 액화가스의 거동
Abstract
The behavior of cryogenic liquid stored in a closed cryogenic tank has been studied at various liquid levels, as a function of pressure and temperature on time, assuming heat leak(NER) is 0.7%/day. The pressure depends, as expected, on the liquid-vapor ratio in a tank. The calculation shows that if liquid level is as high as 90%,much higher than the critical volume ration, in a closed tank of designed pressure 11 bar, it takes 5.4 to 15days for the entire volume of the tank to be filled with liquid and 11 to 22 days for the tank to be exploded. If a closed tank is full of liquid, it is extremely dangerous because of abrupt pressure increase so that the safety devices are necessary to vent out pressurized gas. These phenomena can be explained with the liquid heat capacity, latent heat and compressibility.
Keywords