유체의 점도변화가 펌프성능에 미치는 영향

Effect of Fluid Viscosity Changes on Pump Performances

  • 발행 : 2000.12.01

초록

In order to analyse the effect of the fluid viscosity changes on the centrifugal pump, the computer simulation method and the performance correction chart are used. The centrifugal pump is designed using the traditional method, and the 3D computational grid is generated for the impeller and casing. Working fluids are water, high viscous oil and muddy water. The viscosity of muddy water is measured by the unsteady capillary tube viscometer. The pump performances are predicted well through the computer simulation. The performance curves of head and efficiency for oil and muddy water are decreased. The torques of oil and muddy water, which is calculated by performance correction chart are predicted at a lower value than the computer simulation.

키워드