Measurement of Temperature in Double-concentric Diffusion Flames by Rapid Insertion Technique

급속 삽입범에 의한 동축 이중 확산화염 내부 온도 분포의 측정

  • 정영록 (한양대학교 기계공학과) ;
  • 남평우 (한양대학교 기계공학과) ;
  • 이교우 (한국과학기술연구원 지구환경연구센터) ;
  • 정종수 (한국과학기술연구원 지구환경연구센터)
  • Published : 1999.10.22

Abstract

The temperature distribution in double-concentric diffusion flames have been investigated experimentally by rapid insertion technique. Using a fine thermocouple and rapid insertion mechanism, the temperature has been measured before soot particles attach the thermocouple junction which can affect the temperature signal by changing the radiation heat loss. For double-concentric diffusion flames, the temperature at the axis is higher than that of normal coflow diffusion flames because of the inverse diffusion flame at the center of the flame. However, it is almost same at the periphery on which the inverse flame does not have an effect.