Ducitility Estimation of Exterior Beam-Column Joints using High-Strength Concrete

고강도 철근 콘크리트 보-기둥 접합부의 연성평가

  • 장극관 (서울산업대학교 건축공학과) ;
  • 서대원 (서울산업대학교 건추공학과) ;
  • 황정현 (서울산업대학교 건축공학과)
  • Published : 1999.10.01

Abstract

This paper presents a study in the ductility of reinforced concrete beam-column-slab joints Three assemblies were designed 2/3 scale (f'c=240kg/$\textrm{cm}^2$, f'c=700kg/$\textrm{cm}^2$) and tested to investigate seismic behavior. From the test results, 1) flexural cracks emerge to inside of beam deeply for high strength concrete member, 2) the high-strength specimens degraded in stiffness and strength, and unstable hysteretic behaviors were observed, owing to the brittleness of high-strength concrete beyond its range. 3) The confinement provided by the additional hoops to the column bar is probably the main reason for this improvement in behavior.