Abstract

Since the cement-water reaction is exothermic by nature, the temperature rise within a large concrete mass. Significant tensile stresses may develop from the volumn change associated with the increase and decrease of the temperature with the mass concrete. These thermal stresses will cause temperature-related cracking in mass concrete structures. These typical type of mass concrete include mat foundation, bridge piers, thich walls, box type walls, tunnel linings, etc. Crack control methods can be considered at such stages as designing, selecting the materials, and detailing the construction method. In this paper, the effect of placing of crack control joint or construction joint was analysed by a three dimensional finite element method. As a result, using this method, crack control can be easily performed for structures such as wall-type structures.