Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 1999.04a
- /
- Pages.513-518
- /
- 1999
Push-Over Test of A 10-Story Reinforced Concrete Masonry Infilled Frame with Nonseismic Details
비내진 상세를 가진 10층 철근 콘크리트 조적채움 골조의 일방향 가력 실험
Abstract
The objective of this experiment is to observe the elastic and inelastic behaviors of high-rise reinforced concrete frame with infilled masonry. To do this a building frame designed according to Korean seismic code and detailed in the Korean conventional manner was selected. An 1:12 scale plane masonry-infilled frame model was manufactured according to similitude law. Push-over test were performed under the roof displacement control. To simulate the earthquake effect, the lateral force distribution was maintained to be an inversed triangular by using whiffle tree. From the tests, story displacements, lateral story forces, local plastic rotations and the relations between inter-story drift versus story shear are obtained. Based on the test results, conclusions on the characteristics of the elastic and inelastic behaviors of a high-rise reinforced concrete frame with infilled masonry are drawn.
Keywords