The Investigation of Analytical Techniques for Insulation Characteristics of Oil-Filled Transmission Cables

송전용 OF 케이블의 절연특성 분석방법에 대한 고찰

  • Published : 1999.07.19

Abstract

To find effective diagnostic method for Transmission OF cables, various characterizations were carried such as DGA (dissolved gas analysis), water contents, total acidity and AC breakdown voltage. It was found that the result was varied by sampling and container. The results from those characterization method showed the present condition and history very well and could be used to estimate the degree of degradation of cables.

Keywords