포스트텐션된 3연속 스팬 슬래브의 실험연구

Experimental Study on Post-tensioned 3-Continuous Span Slabs

  • 임재형 (정회원(주) ALT구조 이사, 공박) ;
  • 문정호 (정회원, 한남대 건축공학과 조교수, 공박) ;
  • 이리형 (정회원, 한양대 건축공학부 교수, 공박)
  • 발행 : 1998.10.01

초록

The specimen of current study has the same type with the 3-span slabs of Burns et al used in the study by Mojtahedi/Gamble, which laid a ground for the revision of the ACI318-77 code to the ACI 318-83 code. But those specimens was failed prematurely before it reached the ultimate strength which the specimen had. The reason is that bonded reinforcements were cut off where there is no need for the flexural reinforcement. As results. the slabs failed ultimately where the reinforcements was cut off. Thus, the tendon stresses of failure may have been much smaller than the values which culd reach if the bonded reinforcements were extended beyond the theoretical cut off points. On the based on the fact mentioned above. the specimens which had the same conditions as the specimens of Burns et al were used in the current study, but in which the reinforcements were distributed in a sequence for the reinforcements not to be cut anywhere in the 3-span. As a results, it was known that the current ACI code, revised by the result of Mojtahedi/Gamble's study, overestimated the effect of span/depth ratio on the members with high span/depth ratio. Thus it was concluded that the effect of span/depth ratio on the ultimate stress of unbonded tendon regulated by the current ACI code must be reconsidered and reevaluated.

키워드