Structural behavior of R/C deep beams was investigated and compared to those of specimens with CFRP Grids. Test results show that the crushing of compression strut for the unstrengthened R/C deep beams is changed to the group of several diagonal cracks at mid-depth within the sheat span. Strengthened specimens grow to be more ductile after the redistribution of internal force on the CFRP Grids. The failure mode and variations of strains in the specimens are dependent on the shear span-to-depth ratio. The lower the shear span-to-depth ratio, the bigger failure load and the less variations in strain are observed. Additional anchorage of CFRP Grids does not only cause the improvement in the internal resistance, but also control the brittle shear failure of specimen after reaching the maximum loads.

Keywords