초초고압 CV Cable용(用) 조립형 직선 접속함에서의 Stress Relief Cone 계면압력 최적화에 관한 연구

A Study on the Optimization of Interfacial Pressure for the Stress Relief Cone in the Ultra-High Voltage Level Prefabricated Type Joint Box

  • Baek, J.H. (LG Cable & Machinery Ltd. Electric Power Research & Technology Center) ;
  • Baek, S.Y. (LG Cable & Machinery Ltd. Electric Power Research & Technology Center) ;
  • Lee, S.K. (LG Cable & Machinery Ltd. Electric Power Research & Technology Center) ;
  • Huh, G.D. (LG Cable & Machinery Ltd. Electric Power Research & Technology Center) ;
  • Park, W.K. (LG Cable & Machinery Ltd. Electric Power Research & Technology Center)
  • 발행 : 1998.07.20

초록

Insulation performance of major components of prefabricated joint such as epoxy insulation unit and premolded rubber cone are guaranteed by material selection design and proper manufacturing. On the other hand insulation performance of the interfaces between the premolded rubber cone and the epoxy insulation unit and the cable insulation is maintained by keeping the premolded rubber cone to close contact with such insulation by spring. Electric characteristics of a interface depend on the contact pressure, but the required characteristics are assured so far as a proper contact pressure is maintained. In this report, the interfacial pressure by pressure sensors both in the early stage and after heating cycle were measured and the simulation by FEM program were presented. The comparison of these two results show that interfacial pressure could be controlled optimally by changing the spring length and lubricant state of the interface.