한국소음진동공학회:학술대회논문집 (Proceedings of the Korean Society for Noise and Vibration Engineering Conference)
- 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
- /
- Pages.308-315
- /
- 1997
- /
- 1598-2548(pISSN)
모달필터 성능을 고려한 센서의 최적위치
Sensor Placement in Structural Vibration Control For the Performance of Modal Filter
초록
In this study, the effect of modal filter error on the vibration control characteristics of flexible structures is analyzed for IMSC(Independent Modal Space Control), and optimal sensor placement in the structural vibration control with consideration of performance of modal filter has been studied. An Lyapunov asymptotic stability condition has been derived, which depends on the magnitude of the modal filter errors. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator techniques. A sensor placement technique has also been suggested to maximize the performance of the modal filter. It has been found by a series of simulation that the suggested sensor placement technique is very effective on the determination of the number and placement of sensors of modal filter in the structural vibration control.
키워드