Loss of a Main Feedwater Pump Test at 100% Power Simulation using Korean Standard Nuclear Plant Analyzer (KSNPA)

  • Published : 1996.05.01

Abstract

The Loss of a Main Feedwater Pump test at 100% Power for YGN 4 was simulated in order to verify and validate the KSNPA. The comparison of the test data with the KSNPA prediction results showed reasonable agreement in the trends of the major plant parameters. All plant control systems including NSSS and T/G control systems are properly actuated and stabilized the plant conditions to a new steady state conditions in the KSNPA. From the comparison results, the KSNPA showed its capability to simulate the LOMFP event for the Korean Standard Nuclear Power Plant.