원자로 격납건물 콘크리트의 크리이프 변형 특성

Creep Strain of Containment Concrete Structure

  • 방기성 (한국전력공사 전력연구원 일반연구원) ;
  • 정원섭 (한국전력공사 전력연구원 일반연구원) ;
  • 조명석 (한국전력공사 전력연구원) ;
  • 송영철 (한국전력공사 전력연구원 책임연구원)
  • 발행 : 1996.10.01

초록

Creep, drying shrinkage, modulus of elasiticity and Poisson's ratio of concrete are influenced by a number of factors such as mix type, member thickness, curing condition and loading cases. Particularly, creep and shrinkage in concrete have yet to be studied due to its complicated time-dependent properties. In this study, the concrete creep tests were carried out at varous ages of loading-7, 28, 90, 180 and 365 days in order to investigate and quantify its long-term properties. The test procedures and analysis of the test results were also described herein. The results of this study will enable A/E to calculate effective prestressing forces considering time-dependent prestressing loss and evaluate the structural integrity of the prestressing system using the representative values derived from this property test.

키워드