스플릿트샤프트 장치를 이용한 립실의 접촉력측정

Radial Contact Force Measurement of Lip Seals with a Split Shaft Device

  • 발행 : 1996.10.01

초록

A split shaft device is commonly used to measure the radial force of lip seals. The radial force measured with this device includes some inevitable error. This error is caused by the fact that the split shafts cannot maintain a perfect circle when the interference becomes larger or smaller than some initial interference. In this study, a theoretical model for the calculation of the radial contact force has been carried out, and an explicit equation for the measurement error as a function of the initial interference and the interference to be measured has been obtained. The error when the interference is small is not dependent upon the material properties and the shape of the lip seal, but rather upon the amplitude of the initial interference and the interference to be measured. When the interference is larger or smaller than the initial interference, the measured contact force is always underestimated or overestimated.

키워드